BiRa Systems

CAMAC Products

MODEL 5910

FUNCTION GENERATOR 4-CH, WITH 32K WORD SRAM, MANY RANGES

FEATURES

APPLICATIONS

GENERAL DESCRIPTION

The Model 5910 is a single-width module that contains four 12-bit Digital-to-Analog Converters. The 5910 uses a Model 5903 32K x 12-bit memory for data storage. The 5910 has four differiential analog outputs, switch-selectable for ±10.24V, ±5.12V, 0 to 10.24V, and 0 to 5.12V output ranges. The 5910 can use an external clock provided by a front panel connector, dataway line P2, or an internal clock. The P2 or internal clock, both nominally 1 MHz, has an internal divider to select operating frequencies from 2 KHz to 500 KHz in 7 steps. Memory is partitioned equally among the active channels. Connector options are 2-pin or 3-pin LEMOs.

FUNCTION CODES:

COMMAND Q ACTION
F0 A0 RD1 SCAN Read Memory Data, at Address from address pointer. address is incremented.
F1 An RD2 1 Read channel Status. n is channel # 0 to 3. R1-R3 Number of active channels, R4-R5 Change output voltage range, R6-R8 Module Status; armed and unarmed, active and Dataway mode. R9-R11 Clock Frequency; 200Hz to 50KHz, R12 Clock, 0=Internal, 1=External, R13-R16 SCAN Iterations 0=Continuous Scan, 1-15 = number of iterations
F0 A2 RD1 1 Read Samples per channel.
F6 A0 F06 1 Read Module ID. Decimal 910.
F16 A0 WT1 SCAN Write Memory Data, at Address from address pointer. Address us incremented. Data is binary for unipolar channels and 2's complement for Bipolar channels.
F16 A1 WT1 SCAN Load Address pointer. Command executed if module not armed or active. Loads number of samples to be scanned before a restart at zero location.
F16 A2 WT1 SCAN Write Sample per channel. Command executed if module not armed or active. Loads number of samples to be scanned before a restart at zero location.
F17 A0 WT2 SCAN Write Status Register. W1-W3 number of active channels, W9-W11 Set Clock Frequency, W12 Select Clock: 0= Internal, 1=External, W13-W16 Set SCAN Iterations; 0=Continuous; 1-15 = numberof scans
F24 A0 DIS 1 Disable (STOP) Scan. STOP Scan and disarm the module. DAC outputs go to zero volts.
F25 A0 XEQ 1 Execute (START) Scan. Command executed if module armed but not active.
Z or C CZ or Power Up 0 Sets the module to following state. Sample per channel=full, Clock 200Hz internal, Continuous Scan, Unarmed with output zero, and Channel 1.
X   Valid for all addressed commands.

POWER REQUIREMENTS:

+6 Volts 1860 mA
+24 Volts 450 mA
-24 Volts 390 mA

WEIGHT:

.70Kg. (1 lb. 80z.)

ORDERING INFORMATION:

Model 5910-1 FUNCTION GENERATOR (3 pin LEMO's)
Model 5910-2 FUNCTION GENERATOR (2 PIN lemo'S)
Model 5910-3 FUNCTION GENERATOR (operates with 64K memory)
A- Suffix specifies P2 clock otherwise Internal Clock supplied
Please specify internal clock or p2 clock when ordering

ACCESSORIES:


| Feedback | info@bira.com | Home Page |

Bi Ra Systems, Incorporated
2404 Comanche Road NE
Albuquerque, New Mexico 87107

Ph : 505-881-8887
Fax:505-888-0651