BiRa Systems |
MODEL 5910
FUNCTION GENERATOR 4-CH, WITH 32K WORD SRAM, MANY RANGES
The Model 5910 is a single-width module that contains four 12-bit Digital-to-Analog Converters. The 5910 uses a Model 5903 32K x 12-bit memory for data storage. The 5910 has four differiential analog outputs, switch-selectable for ±10.24V, ±5.12V, 0 to 10.24V, and 0 to 5.12V output ranges. The 5910 can use an external clock provided by a front panel connector, dataway line P2, or an internal clock. The P2 or internal clock, both nominally 1 MHz, has an internal divider to select operating frequencies from 2 KHz to 500 KHz in 7 steps. Memory is partitioned equally among the active channels. Connector options are 2-pin or 3-pin LEMOs.
| COMMAND | Q | ACTION |
|---|---|---|
| F0 A0 RD1 | SCAN | Read Memory Data, at Address from address pointer. address is incremented. |
| F1 An RD2 | 1 | Read channel Status. n is channel # 0 to 3. R1-R3 Number of active channels, R4-R5 Change output voltage range, R6-R8 Module Status; armed and unarmed, active and Dataway mode. R9-R11 Clock Frequency; 200Hz to 50KHz, R12 Clock, 0=Internal, 1=External, R13-R16 SCAN Iterations 0=Continuous Scan, 1-15 = number of iterations |
| F0 A2 RD1 | 1 | Read Samples per channel. |
| F6 A0 F06 | 1 | Read Module ID. Decimal 910. |
| F16 A0 WT1 | SCAN | Write Memory Data, at Address from address pointer. Address us incremented. Data is binary for unipolar channels and 2's complement for Bipolar channels. |
| F16 A1 WT1 | SCAN | Load Address pointer. Command executed if module not armed or active. Loads number of samples to be scanned before a restart at zero location. |
| F16 A2 WT1 | SCAN | Write Sample per channel. Command executed if module not armed or active. Loads number of samples to be scanned before a restart at zero location. |
| F17 A0 WT2 | SCAN | Write Status Register. W1-W3 number of active channels, W9-W11 Set Clock Frequency, W12 Select Clock: 0= Internal, 1=External, W13-W16 Set SCAN Iterations; 0=Continuous; 1-15 = numberof scans |
| F24 A0 DIS | 1 | Disable (STOP) Scan. STOP Scan and disarm the module. DAC outputs go to zero volts. |
| F25 A0 XEQ | 1 | Execute (START) Scan. Command executed if module armed but not active. |
| Z or C CZ or Power Up | 0 | Sets the module to following state. Sample per channel=full, Clock 200Hz internal, Continuous Scan, Unarmed with output zero, and Channel 1. |
| X | Valid for all addressed commands. |
| +6 Volts | 1860 mA |
| +24 Volts | 450 mA |
| -24 Volts | 390 mA |
.70Kg. (1 lb. 80z.)
| Model 5910-1 | FUNCTION GENERATOR (3 pin LEMO's) |
|---|---|
| Model 5910-2 | FUNCTION GENERATOR (2 PIN lemo'S) |
| Model 5910-3 | FUNCTION GENERATOR (operates with 64K memory) |
| A- Suffix specifies P2 clock otherwise Internal Clock supplied | |
| Please specify internal clock or p2 clock when ordering | |
| Feedback | info@bira.com | Home Page |
Bi Ra Systems,
Incorporated
2404 Comanche Road NE
Albuquerque, New Mexico 87107
Ph : 505-881-8887
Fax:505-888-0651