BiRa Systems |
|
MODEL 1601
SMART CRATE CONTROLLER LEVEL ADAPTER (SCCLA)
FEATURES
- RS-485 to ECL adapter for Model 1600 SMART CRATE CONTROLLER (SCC)
- Auxilliary to primary converter for SMART CRATE CONTROLLER
APPLICATIONS
- Convert the output data of the SMART CRATE CONTROLLER to ECL so that it may be connected
to ECL modules such as the LeCroy 1891/92 FastBus-based buffer
- Provided CAMAC pullup resistors and N-line decoding for the SMART CRATE CONTROLLER so
that it may be used as a Primary CAMAC Crate Controller.
GENERAL DESCRIPTION
The Bi Ra model 1601 Smart Crate Controller Level Adapter (SCCLA) is a single-width
CAMAC module. It is an optional companion to the Smart Crate Controller (SCC). The SCCLA
is required to be used with the SCC only if the SCC is to be used as a primary crate
controller; or is to output data in ECLport format; or both. The module basically provides
the SCC with three functional blocks:
- CAMAC control line pullup resistors which are socket mounted and are installed if the
SCCLA is used to support the SCC as a Primary Crate Controller. These pull-ups are removed
if the SCC is already connected to a type CCA2 Crate Controller and is therefore
performing as an Auxiliary Crate Controller.
- CAMAC station number (N) decoder and Look-at-me (LAM) receivers which connect to the SCC
module through the Auxiliary Controller Bus and allow it to function as a Primary Crate
Controller. This connection is not required and thus these functions are format if the SCC
is already connected to a type CCA2 Crate Controller and is therefore performing as an
Auxiliary Crate Controller.
- RS-485 to ECL converters. Without the SCCLA, the SCC data is output in RS-485 format
which is excellent for relatively long distances at high speeds. This format matches RBUF
receiver/buffer modules which reside in VMEbus, model VME1700 VME BUFFER memory module.
With the SCCLA, the SCC data may be converted, if desired, to differential ECL which
matches Lecroy model 1891/92 receiver/buffer modules which reside in FastBus.
POWER REQUIREMENTS
| +6 Volts |
600 mA |
| -6 Volts |
700 mA |
ORDERING INFORMATION
Model 1601 Smart Crate Controller Level Adapter
ACCESSORIES
Auxilliary Bus Cable
| Feedback | info@bira.com | Home Page |
Bi Ra Systems,
Incorporated
2404 Comanche Road NE
Albuquerque, New Mexico 87107
Ph : 505-881-8887
Fax:505-888-0651